Remote Power Control

Raritan's Remote Power Control (RPC) units allow IT administrators to remotely power on/off, reboot, monitor and control power to servers and other network devices. Our full line of intelligent power strips work with other Raritan products to provide integrated remote power management.
Raritan RPC units can be used in data centers and/or remote offices and work with the following Raritan products:

  • CommandCenter Secure Gateway
  • KVM Switches: Dominion® KX II and Paragon II
  • Secure Console Server: Dominion SX
  • KVM/Serial Remote Office switch: Dominion KSX

 

Get the latest information and performance data for our most popular solutions.

Main Units
PCR8A-15 1U horizontal PDU with 8 x IEC C-13 outlets, 230V AC, 10A, 1.9kVA, IEC60320 plug: C-14. Serial connection.
PCR8A-20L6 1U horizontal PDU with 8 x IEC C-13 outlets, 240V AC, 20A, 3.8kVA, NEMA plug: L6-20P. Serial connection.
PCS20A-20 Zero U vertical PDU with 20 x IEC C-13 outlets, 230V AC, 16A, 3.7kVA, IEC60320 plug: C-20. Serial connection.
PCS20A-30L6 Zero U vertical PDU with 20 x IEC C-13 outlets, 240V AC, 30A, 5.8kVA, NEMA locking plug L6-30P. Serial connection.
PCR8A-15-PK 1U horizontal PDU with 8 x IEC C-13 outlets, 230V AC, 10A, 1.9kVA, IEC60320 plug: C-14. Serial connection. Power CIM: P2CIM-PWR
PCR8A-20L6-PK 1U horizontal PDU with 8 x IEC C-13 outlets, 240V AC, 20A, 3.8kVA, NEMA plug: L6-20P. Serial connection. Power CIM: P2CIM-PWR
PCS20A-20-PK Zero U vertical PDU with 20 x IEC C-13 outlets, 230V AC, 16A, 3.7kVA, IEC60320 plug: C-20. Serial connection. Power CIM: P2CIM-PWR
PCS20A-30L6-PK Zero U vertical PDU with 20 x IEC C-13 outlets, 240V AC, 30A, 5.8kVA, NEMA locking plug L6-30P. Serial connection. Power CIM: P2CIM-PWR

Keep your solutions running the way they should with Raritan accessories.

Accessories
D2CIM-PWR CIM for Remote Power Control (RPC) and Dominion PX. Used with Dominion KX II switches only.
P2CIM-PWR Dominion KX and Paragon II CIM for remote power control
CSCSPCS-1-5PK Package of 5 CSCSPCS-1 (0,3m) Cat5e adapters (RJ-45 Male to RJ-45 Female) to connect Dominion SX to RPC remote power control unit

Features

Benefits

Integrated Power Control

Power control integrated with Paragon II, Dominion SX, Dominion KSX, Dominion KX, Dominion KX II and CommandCenter let administrators respond immediately and securely when rebooting is the only way to restore an unresponsive device. No time is lost performing separate sign-ons, launching separate applications or navigating multiple menus.

Web-based GUI

Web browser-based interfaces enable administrators to securely take action from any location in the world.

SSH/Telnet Access

SSH and Telnet access via Dominion SX for quicker Command Line Interface (CLI) control of RPC units. Enables easier client side scripting for automation of power control and monitoring.

Local and Remote Authentication

Inherits the sophisticated local and remote authentication and authorization mechanisms (LDAP, RADIUS, TACACS+, Active Directory) of Dominion Series, Paragon II and CommandCenter.

Power Monitoring

RPC units help prevent outages with true RMS current and voltage monitoring and reporting power consumption, helping administrators balance electrical loads between circuits.

Overload Alarm

User configurable current threshold provides audible and visual alarm on current overload allowing the user to act immediately to protect potential burnouts and interruption of services.

Receptacle Status LED

Individual LED indicator for each receptacle for quick and easy status on physical access.

Vertical and Horizontal Rack Mount Models

RPC units come in a choice of space-saving form factors for vertical and horizontal rack mounting. 1U and 2U units mount horizontally on standard racks. Zero U units mount vertically on rack frames.

NEMA and IEC Plug Types

The 115 VAC units come with various NEMA twist lock and non-twist lock plug types. The 220 VAC units come with IEC and NEMA twist lock plug types.

Receptacle Status Retention

In the case of a power outage, power is restored only to those receptacles that were on before the outage.

 


How much power does a RPC unit need for itself?
The electrical circuitry inside the RPC uses 8W to operate.


What are the default alarm thresholds for PCR8, PCS12, PCS20 and PCR20?
PCR8 - 12 Amps
PCS12 - 16 Amps
PCS20 - 16 Amps
PCR20 - 16 Amps


How do I protect the unit from high-voltage surges and spikes?
This unit must be properly grounded using the earth ground connection next to the circuit.


Why can't I perform the REBOOT command on outlets that are 'Off'?
The REBOOT command executes in this sequence: power OFF, 20-second wait and power ON again. The REBOOT command can only be performed on outlets that are 'On'.


What happens in case of a power overload?
The circuit breaker automatically trips in the case of power overload. Determine the cause of the tripped circuit breaker, correct the problem, and reset the circuit breaker by depressing the button located on the back panel of the PCR8 and PCR20 units, and on the front panels of the PCS12 and PCS20 units.


Is the unit status still accessible through the EIA-232 port even when a power overload occurs, tripping the circuit breaker?
Yes. Power to the unit (electronics, EIA-232 port, etc.) does not go through the circuit breaker. This circuit is protected by a separate ?Amp hardwired fuse. Hence, even if an overload condition occurs, the Remote Power Control unit status menu is still accessible. Circuit Breaker status is reflected on the Status menu. If the breaker is operating properly, the Outlet Circuit Breaker status will read "Good." When there is a problem with the circuit breaker, or if it is tripped, it will read "Fault."


What cables and accessories are required for Integrated Power Management with other Raritan products?

Product

Cable

Adapter

Dominion KX

Cat5

P2CIM-PWR*

Paragon II

Cat5

P2CIM-PWR*

Dominion SX

CSCSPCS-10 (or) CSCSPCS-1

None

Dominion KSX

Cat5

None

*Included with pack (?PK) part numbers, e.g. PCS20?20?PK. Can also be ordered separately.

RELATED PRODUCTS

TAKE THE NEXT STEP

WHAT'S NEW?

Managing power is critical. But where do you start? Raritan and PTS Data Center Solutions examine the myths and realities of power measurement. You’ll also learn how to calculate your data center power efficiency and set standards to align with the Green Grid.

Request White Paper >>


LEARN MORE

HOW TO BUY

To learn more about our solutions, or to buy now, please choose from the following:

Phone: +31 (0)10 284 4040